CJC-1295 without DAC
CJC-1295 without DAC dosage chart: how many units on the syringe
From a 5 mg CJC-1295 without DAC vial reconstituted with 1 mL of bacteriostatic water, a 0.1 mg dose is 2 units on a U-100 insulin syringe. The same 0.1 mg dose reads 4 units if the vial was mixed with 2 mL, and 6 units if mixed with 3 mL. Arithmetic only.
| Dose | Bacteriostatic water | Concentration | U-100 units |
|---|---|---|---|
| 0.1 mg | 1 mL | 5 mg/mL | 2 units |
| 0.1 mg | 2 mL | 2.5 mg/mL | 4 units |
| 0.1 mg | 3 mL | 1.67 mg/mL | 6 units |
| 0.2 mg | 1 mL | 5 mg/mL | 4 units |
| 0.2 mg | 2 mL | 2.5 mg/mL | 8 units |
| 0.2 mg | 3 mL | 1.67 mg/mL | 12 units |
| 0.3 mg | 1 mL | 5 mg/mL | 6 units |
| 0.3 mg | 2 mL | 2.5 mg/mL | 12 units |
| 0.3 mg | 3 mL | 1.67 mg/mL | 18 units |
Computed by the DoseGraph engine at build time, not written by hand. Run your own numbers in the reconstitution calculator.
What the chart calculates
A vial of CJC-1295 without DAC arrives as dry powder. The label states a mass in milligrams and says nothing about volume, because there is no liquid in the vial yet. You create the volume when you add bacteriostatic water, and that choice determines every number on your syringe afterward.
The calculation has two steps. Powder mass divided by water volume gives a concentration in mg per mL. The dose you want divided by that concentration gives a volume to draw. Unit marks on a U-100 insulin syringe are a fixed scale of that volume, so the drawn volume converts directly into a mark on the barrel. The table on this page runs that arithmetic for a 5 mg vial across three water volumes and three dose sizes.
Three things to notice in the table
Water volume moves the unit count in direct proportion. A 0.1 mg dose is 2 units at 1 mL, 4 units at 2 mL, and 6 units at 3 mL. The amount of peptide entering you is identical in all three. Only the water carrying it changes. This is the most common source of confusion: someone copies a unit figure from a source that used different water and draws a different dose than they think.
The same relationship holds for dose size. At a fixed 2 mL of water, 0.1 mg is 4 units, 0.2 mg is 8 units, and 0.3 mg is 12 units. Doubling the dose doubles the marks, with no rounding or hidden loss.
Now look at the two extremes. The 0.1 mg dose in 1 mL sits at 2 units, at the crowded bottom of the scale where a small plunger error is a large dose error. The 0.3 mg dose in 3 mL sits at 18 units, spread across a much wider part of the barrel. More water does not change potency, but it changes how finely you can read what you drew.
Vials other than 5 mg
CJC-1295 without DAC is also sold in 2 mg and 10 mg vials. This table covers the 5 mg vial only, so do not carry its unit figures across to a different vial size.
The direction of the change is easy to reason about. For the same water volume, a larger vial gives a more concentrated solution, so a given dose occupies fewer units. A smaller vial gives a weaker solution and more units. Run the same two-step division with your own vial mass. The practical consequence is that a unit number means nothing on its own. Written down, a dose needs three parts: vial mass, water volume, and syringe type.
What this page does not tell you
There is no reliable human pharmacokinetic data for CJC-1295 without DAC. This site therefore makes no claim about its half life, how quickly it clears, how it behaves across repeated administration, or how long any effect lasts. If you have seen confident timing figures elsewhere, sourcing is the question to ask.
The compound is not approved by any regulator for human use. Nothing here has been reviewed by a clinician, and DoseGraph does not answer clinical questions. That means no guidance on how much to take, no statement about what to expect, no side effect list, and no judgment about safety or effectiveness. The dose amounts of 0.1, 0.2 and 0.3 mg appear in the chart because they are the figures that show up in vendor listings. Their presence is a description of what is sold, nothing more.
Reading the syringe
Draw against the mark, not a mental estimate. Hold the syringe at eye level so the plunger edge and the barrel graduation line up without parallax, and read the leading edge of the rubber stopper rather than its curved tip.
Air in the barrel reads as volume and will short the draw. Invert, tap the bubbles to the top, and push them back into the vial before setting the plunger. When a target lands between graduations, the fix is not a steadier hand but more water at the next reconstitution, which spreads the same dose across more marks.
What we do not know
We hold no reliable human pharmacokinetic data for CJC-1295 without DAC, so this site makes no claims about its half life, how long it takes to clear, or how it accumulates. The arithmetic below concerns concentration and volume only.
This page answers arithmetic and handling questions. It does not tell you what dose to take, what to expect, or whether anything is appropriate for you, and there is no medical review behind it.
Common questions
- How many units is 0.1 mg of CJC-1295 without DAC?
- It depends on how the vial was mixed. From a 5 mg vial in 1 mL of bacteriostatic water, 0.1 mg is 2 units on a U-100 syringe. The same 0.1 mg is 4 units at 2 mL and 6 units at 3 mL. The unit figure is meaningless without the vial mass and water volume attached.
- Does adding more water make the dose weaker?
- No. It makes the solution less concentrated, not the dose smaller. A 0.2 mg dose is 4 units at 1 mL and 8 units at 2 mL from a 5 mg vial, and both draws contain the same 0.2 mg. You are drawing more water alongside it.
- How much bacteriostatic water should I use?
- That is a choice about measurement precision, not about the drug. Less water puts the dose low on the syringe scale where it is harder to read. More water spreads the same dose across more marks. The table shows both ends of that trade for a 5 mg vial.
- What is the half life of CJC-1295 without DAC?
- We hold no reliable human pharmacokinetic data for this compound, so this site publishes no half life, clearance or accumulation figures. Any number you find elsewhere should be traced to its source. The arithmetic here concerns concentration and volume only.
- Can I use this chart for a 10 mg vial?
- No. The table is calculated for a 5 mg vial. A 10 mg vial in the same water volume gives a more concentrated solution, so the same dose lands on a lower unit mark. Redo the division with your own vial mass rather than adapting these figures by eye.
- Does this page say how much to take?
- No. The dose amounts shown are the ones that appear in vendor listings, included so the conversion covers what people encounter. This page has no medical review and takes no position on how much anyone should use. That question belongs with a clinician.
Published 2026-08-20. Last reviewed 2026-08-20. Tier C compound. How we compute this.
When a number here changes, you hear about it
Occasional email: new calculators, new reference tables, and a note whenever a constant on this site is revised. No schedule, nothing else.